IMPORTANT NOTE:
Grade "R" welding hose is for use with acetylene only as specified by the RMA-CGA
Hose Standard.  "T" Grade hose must be used with all other gases.
WARNING:
Do not exceed the maximum working pressures ( regulator setting ) listed for the hoses during
welding and cutting operations.
       Oxygen.............................................................................................150 PSIG Maximum
       Acetylene........................................................................................... 15 PSIG Maximum
       Propane, Propylene, MAPP & all other Fuel Gases............................. 40 PSIG Maximum
In-Service Caution:  The user is first cautioned to shut off the gases at the torch and then at the regulators
or supply source when the torch will no be used for periods in excess of 30 minutes in order to limit permeation
of gas through the hose wall.